Reliability Built To Last

We take pride in designing and manufacturing Variable Frequency Drives that are engineered for unparalleled reliability. With over three decades of experience, we have implemented cutting-edge technology and rigorous testing protocols to ensure that every product meets the highest standards of performance and durability. From design to production, we leave nothing to chance—each VFD undergoes thorough quality checks, guaranteeing long-lasting, consistent operation even in the most demanding environments. We believe in assuring the best quality for each customer and we always aim to deliver the best experience.

Environmental Stress Test Inside Oven

Standards Compliance

PhenomenaStandardTest LevelType of Environment
Harmonics THDIEC 61000-2-412%2nd
All other harmonic orders As per table 24IEC 61000-4-13 class 3As per table 242nd
Commutation notchesIEC 60146-1-1 Class BDepth = 40 %, total area = 250 in % degrees2nd
Voltage deviations (> 60 s)IEC 61000-2-4 Class 2± 10 %2nd
Voltage dipsIEC 61000-4-11 Class 3 or IEC 61000-4-34 Class 3As per Table 52nd
Short interruptionsEC 61000-4-11 Class 3 or
IEC 61000-4-34
Class 3
Volts remaining 0%, Cycles 250/3002nd
ESDIEC 61000-4-24 kV CD or 8 kV AD2nd
Radio frequency electromagnetic field (AM)IEC 61000-4-3As per table 12 IEC61800-32nd
Fast Transient BurstIEC 61000-4-42 kV/5 kHz(power ports)
1 kV/5 kHz Capacitive clamp
(signal interface)
2nd
Surge 1,2/50 s, 8/20 sIEC 61000-4-51 kV line to line 2 kV line to earth2nd
Conducted radio frequency common modeIEC 61000-4-60,15 MHz to 80 Mhz 10 V 80 % AM (1 kHz)
– Power Ports
0,15 MHz to 80 MHz
10 V
80 % AM (1 kHz)
– Signal interface
2nd